| Channels |
1 channel |
|
|
| Dimming
Accuracy |
1024
steps between Off and Full |
| Maximum
Losses |
2%
of load |
| Filtering |
Toroidal
iron powder choke, 120uS rise-time |
| Security
Timing |
Random turn-on
at least 5 minutes once every half hour |
| Timing
Repeatability |
Better
than 1% for all fade timing |
|
|
| Analogue
Input |
0 - 5 Volts
DC control signal, 50K Ohm input impedance |
| Button
Inputs |
Short
to earth operation, 2 mA max pull-up to 5 Volt supply |
| LED
Indicator Outputs |
Pull
down to earth, current limited to 10 mA. |
| Computer
Coms |
33
Baud NRZ, 8 bits, 1 stop, no parity, open collector TTL |
| Control
Connectors |
Moving
cage terminals |
| Control
Wiring |
All
control inputs and outputs may be wired with ELV cable |
| Control
Fuse |
Internal
circuitry protected with 5 Amp HRC fuse (20x5mm) |
| Mains
Isolation |
3500
Volts peak isolation between control circuitry and mains |
|
|
| Output
Load |
8 and 20 Amp
models (derate by 45% for fluorescent loads) |
| Output
Minimum Load |
15
Watts for 10 Amp models, 40 Watts for 20 Amp model |
| Load
DC Component |
Less
than 1 Volt |
| Output
Protection |
n/a |
| Output
Terminations |
Moving
cage terminals |
|
|
| Power
Supply Required |
220
- 240V, 50Hz or 110V, 60Hz depending on model |
| Power
Consumption |
Less
than 4 Watts at no load |
| Power
Terminations |
Moving
cage terminals |
|
|
| Cooling |
n/a |
|
|
| Ambient
Temperature |
0
to 50 degrees Celsius |
| Ambient
Humidity |
95%
maximum, non-condensing |
|
|
| Construction |
Zinc
coated steel, powder coated epoxy paint |
| Front
Panel |
Screen
printed durable epoxy ink |
| Mounting |
Mounting Centres
60mm (8Amp), 80mm (20Amp). Modules should
be mounted vertically in a well ventilated cabinet. |
|
|
| Accessories |
Supplied